The machine runs too hot.
(Pump surface rise up to
about 100 °C (212 °F)).
Continuous operation at too
high suction pressure.
Reduce the suction pres-
sure.
Insufficient cooling. Remove dust and dirt
from the machine.
Ambient temperature too
high.
Observe the permitted
ambient temperature.
Oil level too low. Top up oil.
The oil is not circulating. Conduct an overhaul
(contact Busch).
Oil has deteriorated. Perform a non load oper-
ation with vacuum valve
closed and gas ballast
valve open or replace the
oil.
The machine fumes or ex-
pels oil droplets through the
gas discharge.
Oil level too high. Drain the oil until it gets
the specified level.
Continuous operation is per-
formed at high suction pres-
sure.
Install an oil mist separ-
ator.
Oil mist separator (optional)
is clogged.
Replace the filter element.
Oil mist separator (optional)
is not assembled properly.
Reassemble properly the
oil mist separator.
The oil is emulsified. The machine sucked in li-
quids or significant amounts
of vapour.
Perform a non load oper-
ation with vacuum valve
closed and gas ballast
valve open or replace the
oil.
Modify the operational
mode, )see Conveying
Condensable Vapours
[}14]).
For the solution of problems not mentioned in the troubleshooting chart contact your
Busch representative.