15
15
AUS
8.3 Setting the supply of softened
water
The unit is preset to an:
Inlet water hardness of 20 °d
Blended water hardness of 4 °d
The supply of softened water is set if
– the capacity of the unit is changed
– another inlet water hardness is present
– another blended water hardness is desired
Calculating the supply of softened water:
K x 1000
Supply of softened water = ————————
in litres E - V
K for Bewamat 25 A = 25 m
3
x °d
K for Bewamat 75 A = 75 m
3
x °d
E = Inlet water hardness in °d
V = desired and set blended
water hardness in °d
Press Cange Mode button
Display indicates SEt
Display ashes
Set the calculated soft-water supply
The new supply of softened water is not displayed
until after the next regeneration.
Press Change Mode button to end programming
e.g.
SEt
Uhrzeit
4688 L
3750 L
3750 L
4688 L