2-22 J-Type CCM
J-Type Revision J2005-2
51915< 5HYHU W#0RGH
Revert Mode allows motor faders to return to their original positions if they have been
manually put in their position. The time they take to do this may be programmed (see
below) and the operating circumstances which prompt them to “revert” may be set
as:
OFF Function Off
REC Function enabled when recording a dynamic
REC/PLAY Function enabled when recording or playing back a dynamic
ALWAYS Function always enabled
The option ALWAYS is primarily intended for test purposes.
519163 5HYHU W#7LPH
The time it will take for a motorized fader to resume its original position is set using
the option
Revert Time
in the User Setup in the CCM. Enter a value with the numeri-
cal button and then press
Enter.
519164 )DGH#SURILOH
The movement profile for X-fades may be selected as linear or logarithmic depend-
ing on the application.
Linear profile moves the fader at constant “millimetres per second” which is best for
fading -out sounds.
Logarithmic profile is designed so that two faders moving in opposite directions pass
each other about 4.5 dB down from maximum, creating a suitable panning effect.
Select with arrow buttons, then press
Enter
.