5 Power and water connection
5.1 Preparation for Power and
Water Connection
The following is not supplied and must be provided by
you for the installation:
CAUTION
On the installation side an all-pole separator with a
contact opening width of 3 mm must be provided
per pole for a fixed connection.
➤ Maximum system impedance in the building
connection 0.10 ohms (the impedance can be re-
quested from the energy supplier).
➤ Socket and plug for power connection.
➤ External main switch for power connection.
➤ Supply line and main tap for water connection.
– Maximum water line pressure 0.5 MPa (5 bar).
– Maximum inlet temperature of the water 20 °C.
INFORMATION
Remember to have these preparations
made and to have the appliances at hand on the
day of installation.
DANGER
Danger to life from electric shock!
– The use of sockets with the wrong current will
cause an electric shock and the destruction of
the c35.
WARNING
A damaged appliance is not safe and may cause
serious injuries and a fire.
– Protect the appliance from the effects of the
weather, such as rain, frost and direct
sunlight to prevent damage and potential risks
of injury and fire.
– Do not immerse the appliance or appliance
parts, such as cables and connections, in water.
CAUTION
The connection to the water supply must be in
accordance with standard EN 61770. In addition,
the national rules and laws always apply to the
connection to the water supply.