28
14 Disposal
15 Troubleshooting, Error Messages and Fault Repair
14.1 Disposal of Consumables
Observe the applicable
statutory regulations in your region for the disposal of
consumables and waste.
14.2 Disposing of the Appliance
You can dispose of your c35 at your sales outlet. If you
would like to dispose of your c35 yourself, you must
observe the applicable statutory regulations in your
region for the disposal of the appliance.
15.1 Checklist for Troubleshooting
LC display clear text error display Causes of fault Troubleshooting measures
"Fill milk" "Fill milk" Milk level is too low. Check milk level.
Fill milk.
"Drawer missing" Grounds drawer is not or incorrectly
inserted.
Insert grounds drawer correctly.
"No water" Water connection not correct. Open shut-off valve on the external fresh
water supply.
Check water connection.
"Bean hopper 1 empty" or
"Bean hopper 2 empty"
"Fill beans 1" or
"Fill beans 2"
Bean hopper 1 or 2 is empty
or blocked.
Fill coffee beans.
"Filter" Water filter is used up and must be
replaced.
Contact technical customer service.
"Service coffee" Maintenance request for the entire
system.
Contact technical customer service.
"Service milk" Maintenance request for the milk
system.
Contact technical customer service.
"Piston error" Brewing unit fault
The coffee grounds cake may not
have been ejected.
Insert "USER" chip card and
follow the instructions.
Disconnect coffee machine from the
power supply and re-insert it after 5 sec-
onds. Insert "USER" chip card and wait for
turn on. If the problem persists, contact
technical customer service.
INFORMATION
The most important error messages and diagnosis points can be found at the bottom of the table.
If there are other faults, request the service technician!
If several faults or diagnosis points occur simultaneously, these are indicated alternately
in the status line.
Faults are indicated visually by the flashing dispenser light.