Figure 9 provides a block diagram that details the IP interface mapping.
Figure 9 S320 OCS Ethernet Interfaces Block Diagram
3.4.1 Accessing the Network Configuration Script
A configuration script is included with the software that comes loaded on the S320 OCS.
The following procedure describes how to access and run the network configuration script in
order to modify the system settings:
1. Connect your computing device to the switch’s serial interface (Figure 8).
2. Log in to the system as:
root
3. Go to /etc/gxcnetwork.conf to access the configuration script.
4. Specify configuration values with valid parameters and save the file.
5. Run the gxc-config-network command with the autoconf option to apply the
specified configuration values:
gxc-config-network --autoconf <Path to the Config File>
gxc-config-network --autoconf /etc/gxcnetwork.conf