31
Operatinginstructions
Electric-SystemEVS34/12-DS/IU
CALIRA ElectronicGmbH&Co.KG
Lerchenfeldstr.987600KaufbeurenTel.+49(0)8341/9764-0Fax+49(0)8341/67806
Internet:http://www.calira.deEmail:info@calira.de
Technicaldata
Alternatingcurrent,215 V -245 V/50Hz,singlephase
DC10-15 V frombatteryI
ChargingcurrentforbatteryII,maximum12 A,arithmetic
average,electronicallyregulatedaccordingtotheIUoU
characteristicchargingcurve.
ChargingcurrentforbatteryII,maximum7 A
12V DC
OutputbatteryII,regulatedDC,14.2 V.
Refrigeratoroutput,12 V frombatteryI
Automatic
MainchargingONatbatteryvoltage13.5 V
MainchargingOFFatbatteryvoltage14.4 V
Timersixhoursconstant14.4 V
Holdingcharge,constantat13.8 V
ONwhenvoltageispresentatcontact10
Paralleloperation,bufferoperation,generalcharging
operation
Ambienttemperatureof-25°Cto+35°C.Duringoper-
ation,thehousingmayheatuptoapprox.70°C.
Byconvection
Powersupply
Mainsoperation:
Drivingoperation:
Outputcurrent
Mainsoperation:
Drivingoperation:
Outputvoltage
Mainsoperation:
Drivingoperation:
Chargingprocess:
Automaticswitch.:
Mainsoperation:
Temperaturede- Thevaluesoftheautomaticswitchingrefertoabattery
pendentcontrol temperatureof20°C. Whenusingatemperaturesensor
atthesupplybattery,thesevaluesvaryasafunctionof
thebatterytemperature.
Hightemperature==>loweringofthethresholdvalues.
Lowtemperature==>higherthresholdvalues.
Drivingoperation:
Application:
Temperature:
Cooling:
(optional)