36
Operatinginstructions
Electric-SystemEVS34/12-DS/IU
CALIRA ElectronicGmbH&Co.KG
Lerchenfeldstr.987600KaufbeurenTel.+49(0)8341/9764-0Fax+49(0)8341/67806
Internet:http://www.calira.deEmail:info@calira.de
Connection
Disconnectthepowercablesfromthebatteryand
fromthemainsbeforeconnectingordiscon-
nectinganycables!
Preparetheconnectingcable.Ensurethattheflatsleevesforthecorrectcross-
sectionarepressedfirmlyontothecableends,andaresecurelyattached!Loose
contactsmayleadtoshortcircuitingandtopoorconnection.Cableendsdesig-
nedforusewithcableendsleevesmustnotbesoldered.
Thisdevicecontainscomponentsthatmay
generatesparksorelectricarcing!
Cablecross-sections:
Attachingthemainswitchflatsleeves
Removealengthof5mmofinsulationfromtheconnectingcable(Fig.15).
Pushtheflatsleeveovertheconnectingcable,sothatthebaredpartsitsinthe
frontclamp. Thesecondclampmustenclosetheinsulatedpart(Fig16).
Fig.15
Chargingcable+batt.II
Chargingcable-batt.II
Chargingcablebatt.I
Measuringcablebatt.II
Refrigerator
Consumerupto10 A
Consumerupto15 A
Mainswitchcable
10mm²
2x6mm²
2,5mm²
0,75mm²
2,5mm²
1,5mm²
2,5mm²
2,5mm²
4mm²
0,75mm²
Max. length 1 m
Max length 1 m
Up to 3 m length
More than 3 m length
Up to 3 m length
More than 3 m length
5mm