34
Operatinginstructions
Electric-SystemEVS34/12-DS/IU
CALIRA ElectronicGmbH&Co.KG
Lerchenfeldstr.987600KaufbeurenTel.+49(0)8341/9764-0Fax+49(0)8341/67806
Internet:http://www.calira.deEmail:info@calira.de
Settingup
Length:500mm/ Width:380mm/Height:210mm
Forinitialset-upvariousauxiliarypacksareavailablethathavetobeespecially
ordered.
"QuickPower"quickbatteryconnectorpartno.H10432011000
Temperaturesensorforbatterypartno.H10432011000
Thedeviceshouldbesetupinalocationnotexposedtohumidityanddamp.
Thesettinguplocationmustbeclean,dryandwell-ventilated.Duringope-
ration,thehousingmayheatuptoapprox.70°C. Therefore,maintainamini-
mumcleardistanceof100mmallaround.Ensurethattheventilationslotsare
notcovered.
Thespaceprovidedforthedevicemustnotbesmallerthanthedimensions
specifiedhere,sinceaminimumcleardistanceof100mmmustbeprovidedall
thewayaroundit.
Placethedevicenearthebattery,butalwaysinaseparatebox. Theconnecting
cableshouldbenolongerthan1m. Theseparateboxforthedevicemustbe
providedwithventilationholesatthetopandsides,withatotalareaof
8,000mm². Theboxforthebatterymusthaveaventilationholefacingtowards
theoutside.
Attachthedevicesecurelywiththefourfasteningscrewssupplied.See
fasteningmethod(Figure14). Thelegscanalsobeattachedintheposition
markedwithastar. Todoso,theboltsatthelegsmustbeloosened. Thelegs
canthenberotatedandscrewedtightagaininthenewposition.
Option
(notincluded)