38
Operatinginstructions
Electric-SystemEVS34/12-DS/IU
CALIRA ElectronicGmbH&Co.KG
Lerchenfeldstr.987600KaufbeurenTel.+49(0)8341/9764-0Fax+49(0)8341/67806
Internet:http://www.calira.deEmail:info@calira.de
contact13ofthecouplingplugwithaflatsleevetothenegativeinputofthe
EVS(Figure19).
Connecttheinputcurrentcable(red,2.5mm²)frombatteryIthroughcontact9
ofthecouplingplugwithaflatsleevetothepositiveinputoftheEVS(Figure
19).
Connectthenegativecablefortherefrigerator(blue,2.5mm²)usingaflat
sleevetothenegativerefrigeratoroutputoftheEVS(Figure19).
Connectthepositivecablefortherefrigerator(red,2.5mm²)usingaflatsleeve
tothepositiverefrigeratoroutputoftheEVS(Figure19).
Connectthepositivecablesfromtheconsumerstothepositivedistribution
cable(Figure20).Devices(otherthantherefrigerator)thatneedconstant
voltageareconnectedtothecontinuousoutput(continuouspositive).
Connectthenegativecablesfromtheconsumerstothenegativedistribution
cable(Figure19). Werecommendthatthenegativecablesfortheelectrical
loadsareconnectedtothenegativedistributorinthesamesequencefromleftto
rightasthepositiveoutputsareconnected.
ConnectthenegativecablesfrombatteryIIusingaflatsleevetothe4thand
11thflatconnectorsfromtheleftofthenegativedistributorattheEVS(Figure
19).
ConnectmeasuringcableB+(red,0.75mm²)frombatteryIItothesensing
inputB+oftheEVS(Figure20).Ifthelengthisgreaterthan1m,thecable
mustbeprotectedbya2 A fuseclosetothesupplybattery. Thisfuseserves
exclusivelytoprotectthecircuits.
ConnectthepositivecablefrombatteryIItothepositiveBatt.IIinputofthe
EVS(Figure20).
ConnectingtheRefrigerator
ConnectingConsumers
ConnectingBatteryII
ThepositivecablesfrombatteryIItothedevice
mustbelaidinsuchawaythattheyarenot
mechanicallydamagedorshort-circuited!