2.0 11/2011
© 11/2011 © CAME cancelli automatici s.p.a. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.a. to notify said changes.
ENGLISH
Command devices
Stop button ((N.C.) contact.)
Gate stop button with exclusion of automatic closing, to resume
movement press command button or transmitter button.
If unused, short-circuit contact 1-C2.
Key switch selector and/or command button (N.O. contact)
Commands for opening and closing, by pressing the button or
turning the selector switch key.
7 Selecting functions
1 ON - Automatic closing activated; (1OFF - deactivated)
2 ON - "Open-stop-close-stop" with (2-7) button and radio transmitter;
2 OFF - "Open-close" with button (2-7) and radio transmitter activated.
8 Settings
Trimmer T.R.2M. = Adjusting the delay of operator 2 from 1 minute to 10 seconds.
Trimmer T.L. = Adjusting the working time from 15 seconds to 120 seconds. (Note: adjusting the working time to the
minimum will activate the "maintained action" function).
Trimmer T.C.A. = Adjusting automatic opening and closing times from 0 seconds to 120 seconds.
if unused
T.R.2M
T.L.
T.C.A