ENGLISH
Command devices
Stop button ((N.C.) contact.)
Gate stop button with exclusion of automatic closing, to resume
movement press command button or transmitter button.
If unused, short-circuit contact 1-C2.
Key switch selector and/or command button (N.O. contact)
Commands for opening and closing, by pressing the button or
turning the selector switch key.
7 Selecting functions
1 ON - Automatic closing activated; (1OFF - deactivated)
2 ON - "Open-stop-close-stop" with (2-7) button and radio transmitter;
2 OFF - "Open-close" with button (2-7) and radio transmitter activated.
8 Settings
Trimmer T.R.2M. = Adjusting the delay of operator 2 from 1 minute to 10 seconds.
Trimmer T.L. = Adjusting the working time from 15 seconds to 120 seconds. (Note: adjusting the working time to the
minimum will activate the "maintained action" function).
Trimmer T.C.A. = Adjusting automatic opening and closing times from 0 seconds to 120 seconds.