- 05/2015 - © Came S.p.A. - The manual's contents may be edited at any time without notice.
DIP-SWITCH
1 ON - Automatic Closing - The automatic closing timer activates at the end of the opening gate run. The pre-set time is adjustable,
and is in any case conditioned by the activation of any safety devices, and does not activate after a total safety “stop” or during
a blackout.
2 ON - "Open-stop-close-stop" function with [2-7] button and radio transmitter (fi tted with inserted radiofrequency card).
2 OFF - "Open-close" function with [2-7] button and radio transmitter ((fi tted with inserted radiofrequency card).
3 ON - "Open only" function with radio transmitter ((fi tted with inserted radiofrequency card).
4 ON - Maintained action - The gate works by keeping button pressed (one 2-3P opening button , and one 2-7 closing button).
5 ON - Pre-Opening and closing fl asher - Following and opening and closing command, the fl asher connected to [W-E1], fl ashes for 5
seconds before motion begins.
6 ON - Obstacle detected - When motor is stopped (gate closed or after a total stop command) it prevents any movement if safety
devices, such as photocells, detect any obstacles.
7 OFF - Opening during closing - If the photocells detect an obstacle during gate’s closing, gate motion is inverted until fully opened;
connect the safety device to terminals [2-C1]; if unused, set DIP switch to ON.
8 OFF - Partial stop - Gate stop when obstacle is detected by the safety device; once obstacle is removed, the gate remains still or
closes if automatic closing is activated. Connect the safety device to terminal [2-C3]; if unused, set the DIP switch to ON.
9 OFF - Total stop - This function stops the gate and then excludes any automatic closing cycle; to set in motion again, use either the
keypad or transmitter. Insert the safety device in [1-2]; If unused, set DIP switch to ON.
10 OFF Limit switch slowing activated
DIP-SWITCH
1 ON - Closing only – with command device connected on contact 2-7.
1 OFF - Open-close – with command device connected on 2-7 (see Dip Switch 2 ).
2 ON - Only opening – with command device connected on contact 2-3P.
2 OFF - Partial opening - with control device connected on contact 2-3P. If the automatic closing is deactivated but we still want it after
a partial opening (for a set time of 8"), turn the ACT. trimmer entirely towards +.
3 ON - Optical reader deactivated; to program deceleration you need to activated the optical reader.
4 ON - disconnected
NOTE: make selections when motor is stopped and in the closed position.
6.4 Function selector
Trimmer ACT. =Sets the waiting time while open. Once this time has elapsed, closing automatically takes place. The waiting time may
be set from 1 to 120 seconds.
Trimmer PAR.OP. = Sets the gate’s partial opening. By pushing the partial opening button connected at 2-3P, the gate will open for a
set time between 0 and 16 seconds.
6.5 Settings