Soft start
Set a slowdown of a few seconds after each opening and closing command.
F12 Soft start OFF (Default)
ON
Sensor type
Set the type of control device.
F14 Sensor type 0 = Transponder selector switch
1 = Keypad selector (default)
Additional light
Choose the operating mode of the lighting device connected to the output.
F18 Additional light 0 =Flashing beacon (Default)
1 = Cycle light.
The light remains off if an automatic closing time is not set.
Automatic closure
Set the time before automatic closure is activated, once the opening travel end has been reached.
The function does not work if any of the safety devices are triggered when an obstacle is detected, or after a complete stop, or during a power outage.
F19 Automatic closure OFF (Default)
From 1 to 180 seconds
Automatic closing after partial opening
Set the time before automatic closure is activated, after a partial opening command has been performed.
The function does not work if any of the safety devices are triggered when an obstacle is detected, or after a complete stop, or during a power outage.
Do not deactivate the function [Automatic close].
F20 Automatic closing after partial
opening
OFF
From 1 to 180 seconds (default: 10 seconds)
Pre-flashing time
Set the time for which the beacon is activated before each manoeuvre.
F21 Pre-flashing time OFF (Default)
From 1 to 10 seconds
Gate travel speed
Set the travel speed (percentage of maximum speed).
F28 Gate travel speed 50% to 100% (Default 100%)
Slowdown speed
Opening and closing slowdown speed
This function appears only if the [Encoder] function is active.
F30 Slowdown speed 10% to 50% (Default 50%)