Travel sensitivity
Adjust the obstruction detection sensitivity during boom travel.
F34 Travel sensitivity 10% to 100% (Default 100%) - 10% = maximum sensitivity - 100% = minimum
sensitivity
Slowdown sensitivity
Adjust the obstacle-detection sensitivity level during slowdown.
This function appears only if the [Encoder] function is active.
F35 Slowdown sensitivity 10% to 100% (Default 100%) - 10% = maximum sensitivity - 100% = minimum
sensitivity
Partial opening point
Determine the gate partial opening point, as a percentage of total travel.
This function appears only if the [Encoder] function is active.
F36 Partial opening point 10% to 80% (Default 10%)
Opening slowdown point
Set the opening slowdown start point, as a percentage of total travel.
This function appears only if the [Encoder] function is active.
F37 Opening slowdown point 10% to 60% (Default 25%)
Closing slowdown point
Set the closing slowdown start point, as a percentage of total travel.
This function appears only if the [Encoder] function is active.
F38 Closing slowdown point 10% to 60% (Default 25%)
RSE
Configure the function to be performed by the card inserted in the RSE connector.
F49 RSE 0 =Deactivated (Default)
1 = Paired
3 = CRP
Save data
Save user data, timings and configurations to the memory device (memory roll or USB key).
The function is displayed only when a USB stick is inserted into the USB port or when a memory roll card is inserted into the control board.
F50 Save data 0 =Deactivated (Default)
1 = Activated
Read data
Upload user data, timings and configurations from the memory device (memory roll or USB key).
The function is displayed only when a USB stick is inserted into the USB port or when a memory roll card is inserted into the control board.
F51 Read data 0 =Deactivated (Default)
1 = Activated