28
48 '.$
28
48 '.$
,
.
%##
0.2 03/2010
© CAME cancelli automatici s.p.a. -
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
MASTER COMMAND CARD
SLAVE COMMAND CARD
- Determine the Master and Slave barrier.
8 Connecting two coupled barriers to one command
- on the pre-chosen
Slave command card, set
Dipswitch 7 to ON, perform
power connection on termi-
nal L-N, connect the device
to 10-E terminal output,
adjust to the same speed
and deceleration as for the
Master barrier.
- On the pre-chosen Master
command card, perform
all the connections (see
electrical connections
paragraph)
the installation procedure
for the remote control, set-
tings and adjustments.
MASTER COMMAND CARD
SLAVE COMMAND CARD
- Perform connection between two command cards through RX-TX GND terminals.
Black
Red
Black
Red
Screened cable
2402C 22AWG