F31
Closing slow-down
speed
Setting the barrier's closing slow-down speed, calculated, calculated as a percentage.
Warning! The speed parameter fi elds vary depending on the type of boom:
- for jointed booms of 2 m, set the slow-down speed percentage to between 20 and 40;
- for booms of 4 m, set the slow-down speed percentage to between 20 and 25.
- for booms of 6 m and 8 m, set the slow-down speed percentage to between 15 and 20.
15 = 15% of the maximum speed /… / 40= 40% of the maximum speed
F33 Calibration speed
Setting the boom's travel automatic calibration, calculated as a percentage.
20 = 20% of the maximum speed /… / 40= 40% of the maximum speed (default)
F34 Travel sensitivity
Adjusting obstruction detection sensitivity during gate travel.
10 = Maximum sensitivity /… / 100= Minimum sensitivity (default)
F35
Slow-down
sensitivity
Adjusting obstruction detection sensitivity during slow-down.
10 = Maximum sensitivity /… / 100= Minimum sensitivity (default)
F37
Opening slow-down
point
Percentage adjustment of the boom's total travel, from the beginning of the opening slow-down
point.
Warning! The percentage varies depending on the boom type:
- for jointed 2 m and 4 m booms, set the percentage to between 40 and 60;
- for 6 m and 8 m booms, set the percentage to between 60 and 70.
40 = 40% of the total travel /… / 60 = 60% of the total travel
F38
Closing slow-down
point
Percentage adjustment of the boom's total travel, from the beginning of the opening slow-down
point.
Warning! The percentage varies depending on the boom type:
- for jointed, 2 m booms, set the speed percentage to between 20 and 40;
- for 4 m booms, set the percentage to between 50 and 60;
- for 6 m booms, set the percentage to between 60 and 70;
- for 8 m booms, set the percentage to between 65 and 75;
20 = 20% of the total travel /… / 75 = 75% of the total travel
F40
Closing approach
point
Adjusting, as a percentage of the boom's total travel, the closing approach starting point.
This function only appears if the Encoder function is activated.
1 = 1% of the total travel /… / 20 = 20% of the total travel
F49
Managing the serial
connection
To enable operation in paired, alternate or CRP (Came Remote Protocol) modes.
0 = Deactivated (default) / 1 = Paired / 2 = Alternate / 3 = CRP
F50 Saving data
Saving memorized users and settings in the memory roll.
This feature only appears if a memory roll has been fi tted into the control board.
0 = Deactivated (default) / 1 = Activated
F51 Reading of data
Uploading data saved in memory roll.
This feature only appears if a memory roll has been fi tted into the control board.
0 = Deactivated (default) / 1 = Activated
F52
Transferring
parameters in
paired/alternate
mode
Uploading settings from Master to Slave.
This only appears if the F49 function is set to PAIRED or ALTERNATE.
0 = Deactivated (default) / 1 = Activated
F56 Peripheral number
To set the peripheral number from 1 to 255 for each control board when a system is fi tted with
several operators and features the CRP (Came Remote Protocol) connection system.
1 ----> 255
F60 Sleep mode
For reducing energy consumption by the stand-by photocells.
0 = Deactivated (default) / 1 = Activated
F61 Pre-fl ashing
After an opening or closing command, the fl ashing light connected to 10-E1m fl ashes before
starting the maneuver.
For setting the time, see function F 21.
0 = when opening and closing (default) / 1 = only when closing / 2 = only when opening