Installation Manual June 2018 • Rev. 1.6
NOTE: Tech Support will only be provided where product installation guidelines
have been followed.
Specification Notes
CAUTION: EMERGENCY LOCKDOWN
Emergency lockdown functions must operate totally independent of the access
control system and must not rely on operation of card readers, access control
panels, communications networks, communications devices or host software.
Cansec accepts no responsibility for direct or consequential damages resulting from
the failure of emergency lockdown functions which are dependant in any way on
the operation of card readers, access control panels, communications networks,
communications devices or host software.
Wiring Note:
Improper Wiegand cable (new or originally installed cable or missing required
shield connections) may result in high frequency noise on the data lines creating
misreads. This Wiegand misread issue is more evident on longer Wiegand reader
cables. The reader cable may have to be replaced with the correct type of Wiegand
reader cable to improve system reliability.
MAP1 and H1000 Connector Compatibility:
H1000 connectors can be used on the MAP1 controller. The wiring will have to be
adjusted to accommodate for the reversed connector insertion.