19
LOADING AND SENDING PROGRAMS, Cont.
Load A Program
The steps to load an application program on the 777 are as follows:
1. Apply power to the 777 indicator.
2. While the Start Menu is displayed, press the
NEXT
key. The screen will change to the
LOAD / SEND / DSPLY Menu.
3. Press the LOAD key.
4. The screen will display,
SELECT COM 1 OR COM 2.
5. Press the
COM1
key or the
COM2
key depending on which port you are using to
receive the program OR press the
ESC
key to abort the load procedure and return to
the LOAD / SEND / DSPLY Menu.
6. The screen will display,
RECEIVE?
and the current baud rate selected.
If the baud rate displayed is correct, press the
YES
key to continue.
If the baud rate displayed is incorrect or you wish to use a different rate, press the
BAUD
key. The screen will display the next baud rate available. Continue
pressing the
BAUD
key until the desired baud rate is displayed. Press the
YES
key to continue.
When the
NO
key is displayed, the load procedure may be canceled. Pressing the
NO
key will display,
CANCELLED LOCALLY. Press the
OK
key to return to the
LOAD / SEND / DSPLY Menu.
7. The screen will display the following warning message:
WARNING
APP WILL BE ERASED
PROCEED?
YES NO
8. If the
NO
key is pressed, the operation will be cancelled and the current application
program will be unchanged.
9. If the
YES
key is pressed, the current application program will be erased in preparation
for downloading a new application program.
10. The screen will display
ERASING PROGRAM
and erase
the application currently
stored in the 777 memory.
11. After erasing the program, the screen will display:
SETUP REMOTE TO SEND
PRESS
-
READY
-
TO
CONTINUE
READY
12. Make sure the remote (computer or other 777 indicator) is ready to send, and press
the
READY
key.
13. The screen will display
RECEIVING FROM COMx (x = the com port selected in
step 5), the record number the indicator is receiving and a status message.
14. To stop or pause the load process, press the
ESC
key. The screen will display
QUIT?.
To stop loading (receiving) the program, press the
YES
key. The screen will
display,
CANCELLED LOCALLY. Press the
OK
key to return to the
LOAD / SEND / DSPLY Menu.
Press the
NO
key to continue loading (receiving) the program from the point at
which it was interrupted.