3
SPECIFICATIONS
Displayed Resolution . . . . . . . . 10,000 divisions (commercial)
100,000 divisions (maximum) (non - commercial)
Internal Resolution . . . . . . . . . . 400,000 divisions
Division Value . . . . . . . . . . . . . 1 to 9 X 10, 1, 0.1, 0.01, 0.001 and 0.0001
Sample Rate . . . . . . . . . . . . . . selectable 1 to 60 samples per second
Auto Zero Range . . . . . . . . . . . 0, 0.5 divisions or 1 through 9 divisions
Load-cells . . . . . . . . . . . . . . . . .
Up to twelve (12) 350 load cells (with sense)
Excitation Voltage . . . . . . . . . . 10.75 VDC
Sensitivity Range . . . . . . . . . . . 30 nV/V/ division maximum
Calibration . . . . . . . . . . . . . . . . Digital
Dimensions . . . . . . . . . . . . . . . 280mm W X 245mm H X 220mm D
Weight . . . . . . . . . . . . . . . . . . . 10.5 lb (desktop version)
Construction . . . . . . . . . . . . . . . All steel housing, NEMA 12
Power Requirements . . . . . . . . 90 to 260 VAC 50/60HZ
Temperature Range . . . . . . . . . 14 to 104 °F (-10 to +40 °C)
Printer Output . . . . . . . . . . . . . . RS232 serial
Protocol . . . . . . . . . . . . . . . . . . 9600 BAUD, 8 Data, No Parity, 1 Start, 1 Stop
STANDARD FEATURES
4 "Soft" Keys placed below the display that can be user defined for each application.
Full QWERTY Alphanumeric keys.
Large, back-lit LCD display with light sensor
Time & Date with battery backup.
Ten (10) digits of numeric identification.
Keypad tare.
Gross, tare, net conversion.
One (1) Bi-directional RS232 port (for printers).
One (1) Bi-directional combination RS-232 and RS-485 port.
Selectable and custom filtering.
Integral diagnostics.
101 key PC keyboard interface.
• ⋅One (1) scale input card.