21
English
Make ground connection prior to any other electrical
connections.
All eld electrical connections are the responsibility of
the installer.
WARNING: Make water connections before electrical
connections.
Unit
30AWH
004 006 008 012 015 012 015
V- ph - Hz 230 - 1 -50 400 - 3N - 50
Allowable Voltage Range V 207 ÷ 253 376 ÷ 424
kW 1.65 2.0 2.7 3.85 4.2 6.5 6.5
A 9 11 14.5 20.7 22.6 11.1 11.1
Power Fuses Type gL Type
Current A 10 - Type B 16 - Type B 16 - Type B 25 - Type D 25 - Type D 16 - Type B 16 - Type B
mm² H07RN-F 3 x 2.5 mm
2
H07RN-F 5 x 2.5 mm
2
A 2
2
2
to connect the control to wire SUI
Also check the supply voltage and frequency of the indoor unit.
The unit can be controlled and set via:
• User Comfort Interface wire control 33AW-CS1B
(optional)
• Wire remote control 33AW-RC1 (optional)
• Switches (not supplied)
For the electrical connections refer to Figure 17, while, for
use, refer to the respective manuals.
NOTE: The quality of the contacts must be greater than
25mA @ 12V.
Remove the front panel, the electric parts appear at the
front side.
The power supply cables can be inserted into the pipe
holes. Be sure to x the power cable with bundling band
sold in the market so that they do not make contact with
the compressor and the hot pipes.
To ensure good tensile strength, the electric cables must be
fastened using the cable-holder on the plate.
(Only for sizes 12 and 15 use the strain relief supplied with
the unit). See g 16 for power supply cabling.
Wired control For installation of wired remote controller please refer to the control installation manual.
Power supply Sizethecable,thecablesmustbeH07RN-Ftype.
Accordingtotheinstallationinstructions,alldevicesfordisconnectionfromthepowersupplymainsmusthaveacontactopening(4mm)to
allow total disconnection according to the conditions provided for the overvoltage class III.
Topreventanyrisk,thepowercablemustonlybereplacedbythetechniciansoftheafter-salesservice.
WARNING Forthe3Phunitsbesuretoattachtheprovidedclamplter(11)tothepowersupplywireinordertoconformtoEMCstandard.(Seeg17).