Fig. A — Model Number Nomenclature
Model Series - WeatherMaker
®
FC = Standard Efficiency (EcoBlue™ Technology)
Unit Heat Type
50 = Cooling with Optional Electric Heat
 Packaged Rooftop
Cooling Tons
20 = 17.5 tons
24 = 20.0 tons
28 = 25.0 tons
30 = 27.5 tons
Electric Heat Size
- = No Heat
(Field Installed Available)     
Sensor Options
A =  None
B =  RA Smoke Detector
C =  SA Smoke Detector
D =  RA + SA Smoke Detector
E =  CO
2
F  =  RA Smoke Detector and CO
2
G =  SA Smoke Detector and CO
2
H =  RA + SA Smoke Detector and CO
2
J  =  Condensate Overflow Switch
K =  Condensate Overflow Switch + RA Smoke Detectors
L  =  Condensate Overflow Switch + RA and SA Smoke Detectors
M =  Condensate Overflow Switch + SA Smoke Detector 
N =  Condensate Overflow Switch + CO
2
P =  Condensate Overflow Switch + RA Smoke Detector and CO
2
Q =  Condensate Overflow Switch + SA Smoke Detector and CO
2
R =  Condensate Overflow Switch + RA and SA Smoke Detector and CO
2
Indoor Fan Options - Vane Axial EcoBlue Fan System
2  =  Standard/Medium Static Motor - Vertical Supply
3  =  High Static Motor - Vertical Supply
5  =  Standard/Medium Static Motor - Vertical Supply and Filter Status Switch
6  =  High Static Motor - Vertical Supply and Filter Status Switch
J  =  High Static Motor - Horizontal Supply
L  =  High Static Motor - Horizontal Supply and Filter Status Switch
Refrig. Systems Options
M =  Two Stage Cooling/One Circuit Models
N =  Two Stage Cooling/One Circuit Models with 
 Humidi-MiZer
® 
System
Coil Options – RTPF (Outdoor – Indoor – Hail Guard)
A =  Al/Cu – Al/Cu
B =  Precoat Al/Cu – Al/Cu
C =  E-coat Al/Cu – Al/Cu
D =  E-coat Al/Cu – E-coat Al/Cu
E =  Cu/Cu – Al/Cu
F  =  Cu/Cu – Cu/Cu
M =  Al/Cu – Al/Cu – Louvered Hail Guard
N =  Precoat Al/Cu – Al/Cu – Louvered Hail Guard
P =  E-coat Al/Cu – Al/Cu – Louvered Hail Guard
Q =  E-coat Al/Cu – E-coat Al/Cu – Louvered Hail Guard
R =  Cu/Cu – Al/Cu – Louvered Hail Guard
S =  Cu/Cu – Cu/Cu – Louvered Hail Guard
Voltage
1 = 575/3/60
5 = 208-230/3/60
6 = 460/3/60
Design Revision
- = Factory Design Revision 
Base Unit Controls
0  =  Electro-mechanical Controller - Can be used with 
    field-installed W7212 EcononMi$er IV 
    (Non - Fault Detection and Diagnostic)
3 = SystemVu™ Controller
6  =  Electro-mechanical Controller - Can be used with W7220
    EcononMi$er X (with Fault Detection and Diagnostic)
Intake / Exhaust Options
A =  None
B =  Low Leak Temp Economizer w/ Baro Relief 
 (Electro-Mechanical Controls Only)
D =  Low Leak Temp Economizer w/ PE (cent) Vert Only 
 (EM Only)
F  =  Low Leak Enthalpy Economizer w/ Baro Relief 
 (EM Only)
H =  Low Leak Enthalpy Economizer w/ PE (cent) Vert Only 
 (EM Only)
U =  ULTRA Low Leak Temp Economizer w/ Baro Relief
V  =  ULTRA Low Leak Temp Economizer w/ PE (cent) 
 Vert Only
W =  ULTRA Low Leak Enthalpy Economizer w/ Baro Relief
X =  ULTRA Low Leak Enthalpy Economizer w/ PE (cent) 
 Vert Only
Service Options
0 = None
1  =  Unpowered Convenience Outlet
2  =  Powered Convenience Outlet
3  =  Hinged Access Panels
4  =  Hinged Access Panels and
    Unpowered Convenience Outlet
5  =  Hinged Access Panels and
    Powered Convenience Outlet
6  =  4" MERV 13 High Efficiency Filter Track
7  =  Unpowered Convenience Outlet and 4" MERV 13 
    High Efficiency Filter Track
8  =  Powered Convenience Outlet and 4" MERV 13
    High Efficiency Filter Track
9  =  Hinged Access Panels and 4" MERV 13 High  
 Efficiency Filter Track 
A =  Hinged Access Panels, Unpowered Convenience 
    Outlet and 4" MERV 13 High Efficiency Filter Track
B =  Hinged Access Panels, Powered Convenience 
    Outlet and 4" MERV 13 High Efficiency Filter Track 
Packaging Compliance
0 = Standard
Electrical Options 
A = None 
C =  Non-Fused Disconnect
D =  Thru-The-Base Connections
F  =  Non-Fused Disconnect and
  Thru-The-Base Connections
N =  Phase Monitor/Protection
Q =  Phase Monitor/Protection 
  and Non-Fused Disconnect
R =  Phase Monitor/Protection 
  and Thru-The-Base Connections
T  =  Phase Monitor/Protection with Non-Fused 
    Disconnect and Thru-The-Base Connections
1 = HSCCR Protection
2  =  HSCCR Protection and Thru-The-Base 
  Connections 
Example:
Position:
50FC-M24A2A5-0A0A0
123456789
10
11 12 13 14 15 16 17 18