ELECTRICAL/REFRIGERATION SPECS. ST260RIR
Incubator
Compressor HP117-1-3085
Compressor BTUH / -10°F Evap 1777
Recommended Operating Temp. Range 5°F to 122°F (-15°C to 50°C)
Cabinet Volts 115
Expansion Device Capillary .042 x 14'
Charge Refrig. Type / Oz. / Grams R404A / 15 / 425.2
SYSTEM COMPONENTS
AMBIENT 70°F / 21.1°C 80°F / 27°C 90°F / 32.5°C
Cavity Temp. (F / C) 31 / -2 30 / -2 30 / -2
Suction Pressure (PSIG / Kpa) 16 / 200 18 / 213 21 / 213
Discharge Pressure (PSIG / Kpa) 173 / 1068 198 / 1268 227 / 1358
Compressor Amps 2.4 2.6 2.8
Total Refrigeration Amps 10.8 6.1 10.1
SYSTEM PERFORMANCE
92 ELECTRICAL / REFRIGERATION SPECIFICATIONS