22. SETTING OF SWITCHES
Switch ENC1 : For Setting Cooling Capacity of Indoor Unit
x Switch ENC1 of the PCB of indoor unit is factory used to set the cooling capacity of indoor unit
as per the unit model
Indoor unit models :
12K – 18K – 24K – 30K – 36K – 42K – 48K – 60K
Indoor unit model :
72K
Ducted
Indoor Unit Model
ENC1 Factory Setting
Code
Setting
42KDMT12N-
718
3
42KDMT18N-
718
4
42KDMT24N-718
5
42KDMT30N-
718
7
42KDMT36N-
718T
8
42KDHT42N-
718T
C
42KDHT48N-718T
9
42KDHT60N-
718T
B
Ducted
Indoor Unit Model
ENC1 Factory Setting
Code
Setting
42KDHT
72N-
718T
1
Example :
Ducted split system 53KDMT12N-718
Switch ENC1 is factory set at code 3,
Cooling Capacity 35 i.e 3.5 Kw