12. Function Change (continued)
Functional Parameters
Parameter Description Range
Timer
SLEEP Enable or disable Sleep mode 0 - Off
1 - On
Default: Off
SLEEPWAKE Set a wake-up time - when
Sleep mode will wake up,
ranging from one hour to eight
days from current time. (Only
if Wake Up is ON)
0 - Off
1 - On
Default: Off
Temp
RSTR
Restart temperature for
perishable setpoints in S/S
32.5° to 50°F in 0.5°
increments (0.3° to 10°C)
in 0.1° increments
Default: is 39°F (4°C)
PROBE RAT
or SAT
Indicates the primary sensor
that is used for performing
temperature control in the
system
0 - Return Air
1 - Supply Air
Default: Return Air
Setting
TEMP Determines temperature units
on display
0 - Fahrenheit F
1 - Celsius C
Default: Fahrenheit
This parameter is also
defaulted to "locked" for
NAO Region models.
PRESS Determines pressure units on
display
0 - Psig
1 - Bars
Default: Psig
This parameter is also
defaulted to "locked" for
all NAO Region models.
DATE Determines date format on
display
0 - MM/DD/YYYY
1 - DD/MM/YYYY
Default: MM/DD/YYYY