EasyManua.ls Logo

CAS AD series - E.4..The Span Calibration

CAS AD series
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E.4 THE SPAN CALIBRATION
In this MODE 4, "ULOAd" is shown on the display.
1. Press the "ON/OFF" key,
-> The display shows a count down 9 to 0. -> "LOAd" is shown on the display.
2.
Load a full weight on the platter gently.
3.
Press the "ON/OFF" key,
-> The display shows a count down again, -> The display shows "End" and be
blanked.
4. Remove a full load from the platter.
* If you want to quit this span calibration, press the "ZERO" key while either "ULOAd " "LOAd" is shown on the display.
With above operations, the span calibration is finished, and following
paragraph C. 5 guides to confirm the span and to do a fine trimming for
more accurate weighing.
However when fine trimming is not needed, press the "ZERO" key to skip following
MODE 5 and exit to normal mode.
E.5 CONFIRMATION OF THE SPAN(MODE 5)
This mode 5 is only available after a performance of previous span calibration(mode 4).
1. Press the "TARE" key,
-> The display shows the initial zero point.
2.
Press the "ZERO" key to read a span(net weight),
-> The display shows "0".
3.
Load a full weight on the platter gently.
Unless the display has 30,000 +-1, for more accurate weighing, perform fine trimming.
4. If a span is bigger than 30,000, press the "*" or "kg/lb" key twice for a decreasing and
less than 30,000, press the "*" or "kg/lb" key and touch the "TARE" key for an
increasing.
Whenever you press these keys, a count can be changed.
5.
At the end of fine trimming, press the "ON/OFF" key.
6.
Press the "ZERO" key to exit and enter to normal mode.
-> Weight display shows "Err 2", but actually this error message is not a real error, it prompts only return CAL switch to the normal
position.
7. Return the CAL switch to the normal position(initial position).
or