Chapter 2
4 Case IH 91xx, 92xx and 93xx Series SmarTrax™ Installation Manual
Preparing for Installation
Before installing the SmarTrax system, park the machine where the ground is level, clean, and dry. Bleed
pressure from the hydraulic system and leave the machine turned off for the duration of the installation
process.
During the installation process, follow good safety practices. Be sure to carefully read the instructions in this
manual as you complete the installation process.
Recommendations
Raven Industries recommends the following best practices when installing the SmarTrax system:
• Use part numbers to identify the parts.
• Do not remove the plastic wrap from a part until it is necessary for installation.
• Do not remove plastic caps from a part until it is necessary for installation.
Raven Industries recommends the following best practices when installing or operating the SmarTrax system
for the first time, at the start of the season, or when moving the SmarTrax system to another machine:
• Ensure the machine’s hydraulic filters have been recently changed and there are no issues with the
machine’s hydraulic system (e.g., pump issues, faulty hydraulic motors, fine metal deposits in the hydraulic
hoses, etc.).
• Ensure the machine’s hydraulic valve is using fresh oil and debris is flushed from the hydraulic hoses,
valves, and filters.
Point of Reference
The instructions in this manual assume that you are standing behind the machine, looking toward the cab.
Kit Contents
This section contains a list of the components that are included in the SmarTrax kit. Before beginning the
SmarTrax installation, compare the items in the kit with the components on this list. If you have questions about
the kit, contact your Raven dealer.
TABLE 1. SmarTrax Installation Kit (P/N 117-5032-006)
Picture Item Description Part Number Qty.
Not Pictured
Manual - Case IH 91xx, 92xx and 93xx
SmarTrax Installation
016-5032-006 1
Valve - Hydraulic, SmarTrax, DLS,
PVG32
w/PVES
, 17GPM
334-0003-089 1