– 35 –
3. Press the "FUNCTION" button to perform the "ROM Version check (External)". The conrmation
chords C4, E4, G4 sound.
The "ELEC PIANO", "CLASSIC", "MODERN", "RECORDER" LEDs illuminate and the "R" LED ashes
while on stand-by.
*
If you don’t wish to perform the "ROM version check (External)", go on to the step (1) of the "4. Button
check".
<LEDs on stand-by>
4. Each time you press the "SONG (
u
/
n
)" button, the status of the LEDs changes.
Check to see if the LEDs illuminate in the order shown below.
QC number: 8000501 to 8028031 External ROM (0100): 0 → 1 → 0 → 0 → Stand-by mode
QC number: 8028032 or later External ROM (0103): 0 → 1 → 0 → 3 → Stand-by mode
Sequence
QC number: 8000501 to 8028031 QC number: 8028032 or later
Display LED status Display LED status
1 (0) All LEDs OFF (0) All LEDs OFF
2 (1) "ELEC PIANO" LED (1) "ELEC PIANO" LED
3 (0) All LEDs OFF (0) All LEDs OFF
4 (0) All LEDs OFF (3) "ELEC PIANO" + "CLASSIC" LED
5 ― Stand-by status as in Step 3 ― Stand-by status as in Step 3
* While the external ROM version is indicated, the "R" LED keeps ashing.
4. Button check
1. Press the "FUNCTION" button to perform the "BUTTON check".
The conrmation chords C4, E4, G4 sound, and all LEDs turn off.
2. Press the buttons in the order indicated in the illustration on the bottom.
Each time the button is pressed, the conrmation chord C6 sounds.
If a button is not operating properly or a button is pressed in a wrong order, an error tone (F2) sounds.
* You cannot cancel this test procedure mid-way.
3. When the "ELEC PIANO" button is pressed at the end, the conrmation chords C4, E4, G4 sound and
all LEDs turn off.