If correctly connected, try a Calibration Reset. Press <CAL> and when "FirstZero?"
is displayed press <SELECT> until Cal Reset is displayed. Press <ENTER> to reset
and recalibrate the indicator.
If Calibration Reset does NOT work, hook a load cell simulator up to the indicator to
test and make sure indicator is working correctly.
Troubleshooting
If load cell simulator works fine, hook the load cell back up to the indicator.
Go into setup: 100<SELECT>23640<TIMERS & ADJUST><ENTER>
Key in 110<SELECT> and enter a weight HIGHER than currently in the indicator. If
100 lbs, set to 250. To do this, just key in the desired weight and press <ENTER>.
Once the desired weight is entered, press <ZERO>, when prompted "Enter=Cal!"
press <ENTER> and proceed through calibration.
Once calibrated, if "Cal good?" displays on indicator, press <ENTER> through
remaining prompts.
Troubleshooting
Once back in weigh mode, re-enter setup and go back to parameter 110.
Change the newly keyed in value back to original weight value, and proceed to
calibrate once again by pressing <ZERO> and <ENTER> to re- calibrate.
USE THE NEXT STEPS AS A LAST RESORT!
If this still does NOT fix the issue, the indicator MAY need to be defaulted at P65001.
Key in 100<SELECT>23640<TIMERS & ADJUST><ENTER> to enter setup.
Key in 65001<SELECT> to get "Defit All" and press <ENTER> through the prompts.
The program will NEED to be reloaded and the indicator re-calibrated.