27
DISTRIBUITION BOX “DS520-AN”
PROTECTION FUSES
10) 3A fuse to give power to spark ignitions (fridge,
oven) and gas valve, it is connected directly to
the leisure battery (B2).
13) 20A fuse to give power to lights group “A”.
15) A fuse to protect the OUT D+ simulated exit.
14) 20A fuse to give power to lights group “B”.
16) AES fridge connection; It is a bridge, which
excludes the 3 way function fridge and is used to
connect the AES fridge directly to the B2.
11) Not actived.
17) Output + for the control of the auxiliary relais
(e.g. motorized step, AES fridge, electric water
discharge valve, electric antenna motor, etc.)
which works only when the engine is started.
12) 10A fuse to give power to the water pump.
4) 20A fuse to give power to TV sockets.
6) 30A fuse to give power to 12V AES and 3-way
fridge. The 3-way fridge turns off automatically
when engine is off.
7) 10A fuse to give power to the heating / boiler.
8) 20A fuse to give power to the AUX direct exit, it is
connected directly to the leisure battery (B2).
9) 25A fuse to give power to the motorized step, it
is connected directly to the leisure battery (B2).
2) 3A fuse for the gas pump supply.
5) 15A fuse to give power to the RH auxiliary exit.
3) 15A fuse to give power to the RH auxiliary exit.
1) 5A fuse to give power the AUX auxiliary exit
( )awning light , turns automatically off when
engine is on.
1 2 1 2
8
9
1 10
2 11
3 125 147
4 136 15
-B2 +B2 + OUT 12V
1 2 3 4
1 2 3 4
1
9
8
16
28
20 21
16
19
24
25
31
30
29
+B1
32
17
12
26A
26B
27
22
1 2
23
1
4
3
2
18
RE-VI
RE-EL
POT
EN