CEBORA S.p.A. 8
3.2.2 - Power Source operation.
WARNING!
DURING THE FOLLOWING TESTS DO NOT AIM THE TORCH AT PEOPLE OR PARTS
OF THE BODY, BUT ONLY TOWARDS AN OPEN SPACE OR THE WORKPIECE.
NOTES
Operations preceded by this symbol refer to operator actions.
♦ Operations preceded by this symbol refer to machine responses that must occur following an
operator action.
System shut off and disconnected from the mains.
Connect the gas supply to the fitting (I) on the rear panel.
Connect the torch to the Power Source.
Connect the ground cable of the workpiece to the positive pole (E) of the Power Source.
Connect the Power Source to the mains.
Close the switch (A) on the Power Source.
♦ System powered, on the operator panel all leds and displays are lit (lamp-test).
♦ After one second, display (U) reads “956” and display (V) shows the Power
Source Firmware version.
♦ After one second, displays (U) and (V) indicate the type of torch connected to the
Power Source (e.g.: 161 – CP and then LEn - 6). The fan (23) starts running. The
transformer (37) pre-magnetization and the DC-capacitor (20) pre-charge phases
take place during this time, and when these phases are completed the contactor (2)
closes.
♦ After three seconds, display (U) shows the value of the programmed current and
display (V) shows the set nozzle hole diameter.
Correct?
NO (see 3.3.1, 3.3.2, 3.3.3).
YES
Press the key (W) several times to select the type of operation.
Turn the knob (L) of the pressure regulator (I) for a pressure value, read on the regulator (I)
gauge, adequate to the selected working operation type (see Instruction Manual).
♦ Each time the key (W) is pressed, the leds (N)(O)(P) light in sequence, to
indicate the type of work to be carried out.
♦ Displays (U) and (V) display the current and diameter values assigned to the
operation selected with key (W) and adjustable with knob (Z).
Correct?
NO (see 3.3.3).
YES
Press the key (W) to select the CUT operation (led (N) lit).
Turn the knob (Z) for a cutting current suited to the type of workpiece to be cut (see
Instruction Manual).
♦ Display (U) and (V) show the set cutting current and the suggested nozzle
diameter.
3.302.269 12/04/2012