Equivalent total vibration value CF-2116 D a
hv, eq
= 12 m/s²
Measurement uncertainty K = m/s²
The given values can vary depending on the operating conditions (material to be cut, state of the machine, han-
dling, user, diamond tools in use, etc.).
When determining the daily vibration load A (8) acc. to DIN EN ISO 5349-2, the real effective time must be consid-
ered which can be signicantly inuenced (reduced) by idle times. Idle times include times for fuelling, water supply,
tool change, machine set-up and transport, securing the location of operation/use.
Measurement uncertainty acc. to DIN EN 12096.
DANGER
Risk of injury when exceeding the daily maximum of vibration load!
2.2 Vibration acceleration values, hand-arm vibration