EasyManua.ls Logo

Centurion D5 - LED Indicator Lights

Centurion D5
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NAME
COLOUR ON OFF REMARKS
TRG
Red
Signal present
Signal present
Signal present
Signal present
No signal
No signal
No signal
No signal
N/A
IRB
Green
Safeties clear
Safeties obstructed
N/A
FRX
Red
N/A
PED
Red
N/A
LCK Green
System ready to
operate
System locked
N/A
SET
Red
N/A
STATUS
(During
normal
operation)
Red
Gate fully open Gate fully closed
STATUS
(During
programme
mode)
Red
The number of flashes correspond to the
STATUS or COUNT value being set.
L1
(During
normal
operation)
Red
Origin diagnostic
(Changes state to indicate origin status)
Off when gate is on "CLOSED" side.
On when gate is on "OPEN" side.
L1
(During
programme
mode)
Red
If LED2 also on,
system reset to
factory default.
The number of flashes corresponds with
the FEATURE number being selected
Table3 LED Indicator Light Description & Purpose
L2
(During
programme
mode)
Red
System in programme
mode.
If L1 also on,
system reset to
factory default.
L2
(During
normal
operation)
Red
DOSS diagnostic
(Changes state to indicate DOSS pulses)
Page 45
LED Indicator LightsLED Indicator Lights
The controller is fitted with diagnostic LED's (Light Emitting Diodes) that assist with the set-up and
maintenance of the gate. Table 3 provides a description and purpose of the indicator LED's. See page 40
for location.
Off - Gate is closed.
Slow continuous flash - Gate is opening.
On - Gate is open.
Fast continuous flash - Gate is closing.
1 Flash/sec - Pillar light on permanently.
2 Flashes/sec - No mains.
3 Flashes/sec - Battery low detection.
4 Flashes/sec - Collision detector operated.
5 Flashes/sec - Microprocessor reset.
CHARGER
ON
Green
Battery charging
No charge voltage
present.

Other manuals for Centurion D5