3-273-27
14 - ACC SMOOTH
15 - INV SMOOTH
16 - STOP SMOOTH
17 - THROTTLE 0
18 - FREQ CREEP
DESCRIPTION MIN. MAX STEP UNIT
Determines the acceleration delay in the range between 0Hz and the
frequency established by the STOP SMOOTH parameter:
04.50.5Sec
Minimum setting = maximum acceleration
Maximum setting = minimum acceleration
DESCRIPTION MIN. MAX STEP UNIT
Determines the reverse acceleration delay in the range between 0Hz
and the frequency established by the STOP SMOOTH parameter:
0364Sec
Minimum setting = maximum acceleration
Maximum setting = minimum acceleration
DESCRIPTION MIN. MAX STEP UNIT
Determines the end of the acceleration and inversion delays
established by the ACCELERATION SMOOTH and INVERSION
SMOOTH parameters:
4222Hz
Minimum setting = minimum delays
Maximum setting = maximum delays
DESCRIPTION MIN. MAX STEP UNIT
This parameter determines a 0 value zone in the acceleration bend 0 18 2 %
Image reference 2
DESCRIPTION MIN. MAX STEP UNIT
Determines the minimum frequency applied to the motor 0.1 1.0 0.1 Hz
Image reference 2