3-55
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
E
2 LEARN TRAC POT
Accelerator potentiometer acquisition
The traction potentiom-
eter acquisition must
be repeated whenever
the MCB card or poten-
tiometer is replaced.
If the display does not
memorize the acquisi-
tion data, repeat the
SERIAL NUMBER
acquisition and then
repeat all the other
acquisitions
Re
f.
Function
Description Notes
LEARNING
LEARN TRAC POT
LEARN TRAC POT
OK
To enter the menu and
start acquisition
PRESS FW PED AND
RELEASE THEN BW
PED AND RELEASE
THEN PRESS OK
OK
To end acquisition
LEARN
LEARN TRAC POT
SUCCESSFUL
OUT
To return to the first screen
Press the accelerator pedal (forwards)
to the limit and release slowly
Repeat the operation with
the backwards pedal (if present on the truck)
https://www.forkliftpdfmanuals.com/