Setting BDI ADJ MIN
The indicator may be set to modify the minimum battery voltage at which the last square switches off
(indicator at 0%).
At the end of discharging, the density value of the battery elements must not fall below 1.13 kg/l
[POINT1]
Access the SERVICE menu (see chapter 3, paragraph
SERVICE MENU DESCRIPTION). Modify the value in the
SERVICE -> TRUCK CONF -> BATTERY -> menu,
parameter BDI ADJ MIN to increase or decrease the
maximum battery discharge.
Remarks:
Periodically check the electrolyte density in the battery
elements at the end of discharge.
If the density is lower than 1.13 kg/l, increase the
parameter BDI ADJ MIN by a value of +1.00% (0.24 V)
for every 0.01kg/l up to the limit of 1.13 kg/l.
Remarks: The values shown in the various figures are indicative
BDI ADJ MIN
- 4,00 %
SERVICE MENU
PASSWORD
TRUCK CONF
BATTERY
Press twice
Press OK and then 3 times
Press OK and then once
Press OK
to modify
OK to save/confirm
OUT to return to the previous menu