3-233-23
TRACTION FUNCTION
The Traction function is used to view/modify the traction system parameters.
1 - T TURTLE CUTBACK
2 - T CURVE CUTBACK
3 - T BRAKE CUTBACK
DESCRIPTION MIN. MAX STEP UNIT
Determines the speed reduction of the turtle function 0 100 10 %
Minimum setting = maximum reduction
Maximum setting = no reduction
DESCRIPTION MIN. MAX STEP UNIT
Determines the speed reduction in curve: 0 100 10 %
Minimum setting = maximum reduction
Maximum setting = minimum reduction
DESCRIPTION MIN. MAX STEP UNIT
Determines the deceleration ramp when one or more
speed reduction requests are active.
5.5 15.0 0.5 Sec
The parameter acts on the reductions:
T TURTLE CUTBACK
T SPEED CUTBACK
ACC + BRAKE REDUCT
Minimum setting = maximum reduction
Maximum setting = minimum reduction