Page #108 background image
3-24
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
E
4 - T SPEED CUTBACK
5 - ACC + BRAKE REDUCT
DESCRIPTION MIN. MAX STEP UNIT
This parameter determines the traction speed reduction in relation to
the state of the microswitch (normally closed N.C.) between pin 13
connector JT and pin 9 connector JT:
0 100 10 %
Microswitch open = reduction on
Microswitch closed = reduction off
Minimum setting = maximum reduction
Maximum setting = no reduction
DESCRIPTION MIN. MAX STEP UNIT
Determines the speed reduction when the accelerator pedal is pressed
and the service brake pedal microswitch activated:
0 100 10 %
Minimum setting = maximum reduction
Maximum setting = minimum reduction