3-36
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
E
OPTIONS FUNCTION
The options function is used to enable/disable the machine configuration options.
MOTORS FUNCTION
The motors function is used to enable/disable the electric motor parameters.
N
o
Parameter Description Notes
1 LOCK SET
This parameter enables/disables the LPH push button working:
ON = LPH function disabled
OFF = LPH function enabled
ON-OFF
2 START ICON
This parameter determines which logo must be visualized at the start-
ing
Cesab-BT
3 PIN CODE
Enables/Disables the PIN CODE entry request when switching on:
NONE = disabled
DISPLAY = enabled
4 DY PIN ENABLE Determines the number of Pin Codes enabled 1÷40
5 SWAYING PEDAL
This parameter enables/disables with balanced pedal system
ON = enabled
OFF = disabled
Note: if the parameter is modified the traction potentiometer acquisition must be
repeated
ON-OFF
6 GEAR RATIO
This parameter determines the reduction ratio of the reduction gear in
relation to the truck speed calculus
n°
N
o
Parameter Description Notes
1 T MAX CURRENT
Determines the drive motor current expressed as a percentage of
the maximum current:
- min. setting = min. current
- maximum setting = maximum current
%
2 P MAX CURRENT
Determines the lifting motor current expressed as a percentage of
the maximum current:
- min. setting = min. current
- maximum setting = maximum current
%
https://www.forkliftpdfmanuals.com/