3-37
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
E
RESET FUNCTION
Reset of the hours counter and Fingertips-Joystick configuration
BATTERY FUNCTION
Used to modify the battery indicator parameters.
No Parameter Description Notes
1 RESET JOY FLAG
MCB board configuration reset
(Mechanical/electro-proportional distributor)
2 RESET PUMP HM Pump hours counter reset
3 RESET TRAC HM Traction hours counter reset
4 RESET KEY HM Key hours counter reset
N
o
Parameter Description Notes
1 BDI RESET
Determines the minimum recharge the battery has to receive for the
partial or total reset of the indicator.
(See chapter 1 paragraph BATTERY MANAGEMENT)
%
2 BDI ADJ MIN
Determines the voltage below which the battery indicator signals
0% residual charge
(See chapter 1 paragraph BATTERY MANAGEMENT)
%
3 BDI ADJ MAX
Determines the voltage above which the battery indicator signals
100% charge
(See chapter 1 paragraph BATTERY MANAGEMENT)
%
4 ADJUSTMENT 3
Determines the reset curve
(See chapter 1 paragraph BATTERY MANAGEMENT)
%
5 BDI GEL
Enables the discharge curve for GEL batteries
(See chapter 1, paragraph ADJUSTING THE GEL BATTERY INDI-
CATOR)
ON/OFF