VALVE CURRENT FUNCTION
Displays and modifies the currents of the solenoid valves of the electro-proportional distributor.
No Parameter Description Notes
1 MIN CURRENT DRAIN
Determines the min. current of the DRAIN coil
min. = 100 mA
max. = 500 mA
A
2 MAX CURRENT DRAIN
Determines the max. current of the DRAIN coil
min. = 100 mA
max. = 500 mA
A
3 MIN CURRENT LOWER
Determines the min. current of the lower coil
min. = 100 mA
max. = 500 mA
A
4 MAX CURRENT LOWER
Determines the max. current of the lower coil
min. = 100 mA
max. = 500 mA
A
Total valve opening
MIN CURR:
Increasing or decreasing the value affects the sensitivity of the fingertip control in the initia
MAX CURR:
Increasing or decreasing the value affects the maximum opening of the valve.
100
200
700
600
500
1500
Zone not to be used
MIN CURR
MAX CURR
100%
mA
Valve