EasyManua.ls Logo

Cessna T188C - Trouble Shooting

Cessna T188C
624 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MODEL
188
&
T188
SERIES
SERVICE
MANUAL
12-4.
TROUBLE
SHOOTING
(Cont).
TROUBLE
PROBABLE
CAUSE
REMEDY
NO
FUEL
QUANTITY
Fuel
tank
empty.
Service
with
proper
grade
and
INDICATION
amount
of
fuel.
Circuit
breaker
open
or
de-
Reset.
Replace
if
defective.
fective.
Loose
connections
or
open
Tighten
connections;
repair
or
circuit.
replace
wiring.
Defective
fuel
quantity
indi-
Refer
to
Section
15.
cator
or
transmitter.
12-5.
TROUBLE
SHOOTING.
(Fuel-Injected
Engine).
NOTE
This
trouble
shooting
chart
should
be
used
in
conjunction
with
the
engine
trouble
shooting
chart
in
Section
11A.
TROUBLE
PROBABLE
CAUSE
REMEDY
NO
FUEL
FLOW
TO
ENGINE-
Fuel
shut-off
valve
not
turned
on.
Turn
fuel
shut-off
valve
on.
DRIVEN
FUEL
PUMP
Fuel
tank
or
cells
empty.
Service
with
proper
grade
and
amount
of
fuel.
Fuel
line
disconnected
or
broken.
Connect
or
repair
fuel
lines.
Fuel
tank
outlet
screen
plugged.
Remove
and
clean
screen
and
flush
out
fuel
tank.
Defective
fuel
shut-off
valve.
Remove
and
repair
or
replace
shut-off
valve.
Plugged
fuel
strainer.
Clean
strainer
and
screen.
Defective
check
valve
in
electric
Repair
or
replace
electric
fuel
fuel
pump. pump.
Fuel
line
plugged.
Clean
out
or
replace
fuel
line.
FUEL
STARVATION
Partial
fuel
flow
from
the
pre-
Use
the
preceding
remedies.
AFTER
STARTING
ceding
causes.
Malfunction
of
engine-driven
fuel
Refer
to
Section
11A.
pump
or
fuel
injection
system.
Fuel
vent
line(s)
plugged.
Refer
to
paragraph
12-8
or
12-11.
Water
in
fuel.
Drain
strainer,
tank
or
cells,
and
lines.
NO
FUEL
FLOW
WHEN
Defective
fuel
pump
switch.
Replace
defective
switch.
ELECTRIC
PUMP
IS
TURNED
ON
Defective
throttle
switch.
Replace
defective
switch.
Open
or
defective
circuit breaker.
Reset;
replace
if
defective.
12-3