EasyManua.ls Logo

Cessna T188C - Manifold Pressure Gage; Tachometer; Description

Cessna T188C
624 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MODEL
188
&
T188
SERIES
SERVICE
MANUAL
15-19.
ENGINE
INDICATORS.
NOTE
Before
replacing
a
tachometer
cable
in
hous-
15-20.
TACHOMETER.
ing,
coat
lower
two
thirds
with
AC
Type
ST-
640
speedometer
cable
grease
or
Lubriplate
15-21.
DESCRIPTION.
The
tachometer
is
a
me-
No.
110.
Insert
cable
in
housing
as
far
as
chanical
indicator
driven
at
half
crankshaft
speed
by
possible,
then
slowly
rotate
to
make
sure
it
a
flexible
shaft.
Most
tachometer
difficulties
will
be
is
seated
in
the
engine
fitting.
Insert
cable
found
in
the
drive-shaft.
To
function
properly,
the
in
tachometer,
making
sure
it is
seated
in
shaft
housing
must
be
free
of
kinks,
dents
and
sharp
drive
shaft,
then
reconnect
housing
and
torque
bends.
There
should
be
no
bend
on
a
radius
shorter
to
50
pound-inches
(at
instrument).
than
six
inches
and
no
bend
within
three
inches
of
either
terminal.
If
a
tachometer
is
noisy
or
the
15-22.
MANIFOLD
PRESSURE
GAGE.
pointer
oscillates,
check
cable
housing
for
kinks,
sharp
bends
and
damage.
Disconnect
cable
at
tach-
15-23.
DESCRIPTION.
The
manifold
pressure
gage
ometer
and
pull
it
out
of housing.
Check
cable
for
is
a
barometric
instrument
which
indicates
the
ab-
worn
spots,
breaks
and
kinks,
solute
pressure
in
the
intake
manifold
in
inches
of
mercury.
The
fuel
flow
and
manifold
pressure
indi-
cators
are
in
one
instrument
case,
however,
each
instrument
operates
independently.
15-24.
TROUBLE
SHOOTING.
TROUBLE
PROBABLE
CAUSE
REMEDY
EXCESSIVE
ERROR AT
EXISTING
Pointer
shifted.
Replace
instrument.
BAROMETRIC
PRESSURE.
Leak
in
vacuum
bellows.
Replace
instrument.
Loose
pointer.
Replace
instrument.
Leak
in
pressure
line.
Repair
or
replace
damaged
line,
tighten
connections.
Condensate
or
fuel
in
line.
Blow
out
line.
JERKY
MOVEMENT
OF
Excessive
internal
friction.
Replace
instrument.
POINTER.
Rocker
shaft
screws
tight.
Replace
instrument.
Link
springs
too
tight.
Replace
instrument.
Dirty
pivot
bearings.
Replace
instrument.
Defective
mechanism.
Replace
instrument.
Leak
in
pressure
line.
Repair
or
replace
damaged
line,
tighten
connections.
SLUGGISH
OPERATION
OF
Foreign
matter
in
line.
Blow
out
line.
POINTER.
Damping
needle
dirty.
Replace
instrument.
Leak
in
pressure
line.
Repair or
replace
damaged
line,
tighten
connections.
EXCESSIVE
POINTER
VIBRA-
Tight
rocker
pivot
bearings.
Replace
instrument.
TION.
Excessive
panel
vibration.
Replace
defective
shock
panel
mounts.
15-8

Table of Contents

Related product manuals