15-18. TROUBLE
SHOOTING
--
ALTIMETER.
NOTE
Refer
to
paragraph
15- 13
before
blowing out
pitot
or
static
lines.
TROUBLE
PROBABLE
CAUSE
REMEDY
INSTRUMENT
FAILS
TO
Static line
plugged.
Blow
out
lines.
OPERATE.
Defective
mechanism.
Replace
instrument.
INCORRECT
INDICATION.
Hands
not
engaged.
Reset
hands
with
knob.
Leaking
diaphragm.
Replace
instrument.
Pointers
out
of
calibration.
Replace
instrument.
HAND
OSCILLATES.
Static
pressure irregular.
Blow
out
lines,
tighten
connections.
Leak
in
airspeed
or
vertical
Blow
out
lines,
tighten
connections.
speed
indicator
installations.
15-7