43
Menu - 5 - Combustion rate control mode
Effect Display
The combustion rate control mode will not operate if:
- the boiler is in stand-by mode
- the room thermostat is not calling for heat
- the boiler has locked out
- after a reset or if the main supply fails
- end of the mode if the operator leaves Menu 5
- after 15 minutes if no keys are pressed
Note : As soon as the combustion rate control mode is on the Central Heating temperature control knob will
become inactive.
DISPLAY
A
CTION
C
ONFIGURATION
C
ombustion rate control mode OFF
Combustion rate control mode ON The main exchanger temperature
appears on the display.
The digit - on the display shows the gas
o
utput level.
(Top = maxi, bottom = mini).
Gas output setting To modify the gas output use the and
keys.
To cancel the combustion rate control mode press the key.
once
x times
once