Menu - 6 - External Sensor Settings
DISPLAY
ACTION CONFIGURATION
once
x times
Factory
setting
S
ection
D
igit 1
D
igit 2
D
igit 3 and 4
E
xternal Sensor Fitted
6 0
0 : External sensor fitted
1 : No external sensor
(
factory setting)
Automatic heating
adjustment active
6 1
0 :
Inactive - External Sensor not
fitted (factory setting)
1 : Active - External Sensor fitted
Thermal Curve
(see table
D)
6 2
0.3
0.5
1
1.2
1.5
2
2.5
3
Parallel Shift
(see table
E)
6 3
from 0 to 20
(in steps of 1)
In the event of connection of the external sensor, you must:
1. Activate the external senor (menu 6.0)
2. Activate the automatic heating adjustment (menu 6.1)
3. Select the correct thermal curve (menu 6.2)
4. Adjust the parallel shift (menu 6.3)
NOTE:SEE SECTIONS 14.6, 14.7 AND 14.8 (PAGES 33 & 34) FOR INSTRUCTIONS ON SETTING THE ABOVE.