45
C
H anti cycling delay setting :
If you would like to change the setting of CH anti cycling delay to 3 mins, please proceed as follows:
(NOTE : the factory setting is 2 min 30 seconds and the following explanation refers to Menu 4 Section 8)
Display
17. Adjustments and Setting (continued)
1
5 ”
2
x 3
1
2
or
3
3
4
4
S
witch to installer mode, press the
and keys for 5 seconds, the
display shows :
10=0 if there is no
default in the default register.
Press the menu key three times
to gain access to menu
4, the display
shows :
40=0 or 40=1
Change to section 8 (CH anti-cycling
delay), press the key eight times,
the display shows :
48=2.5 (factory
setting 2 min 30 secs)
4 = menu 4
8 = section 8
2.5 = 2.5 min (2 min 30 seconds)
Press the setting key
once, the
3rd and 4th digits flash together.
Then press the key to change
the CH anti-cycling delay, the display
shows:
48=3.0 press the setting key to
confirm the value. The display stops
flashing.
To exit from setting mode, leave the
boiler for approx. 1 minute the boiler
will automatically switch back to the
user mode.
After programming please close the
door
P (Fig. 46)
x 8