LOCKS
MAGLOCK (2 Terminals, N.C. and COM)
Relay contact output, Normally - closed (N.C.) output for maglocks.
Relay activates prior to motor activation and during motor run. Relay is
off when motor is off.
NOTE: For AC power install a Siemens S10K30 MOV (Metal Oxide
Varistor) or equivalent. For DC power install a 1N4005 diode or
equivalent.
SOLENOID (2 Terminals, N.O. and COM)
Normally - open (N.O.) output for solenoid locks
Relay activates prior to motor activation and during motor run. Relay is
off when motor is off.
NOTE: For AC power install a Siemens S10K30 MOV (Metal Oxide
Varistor) or equivalent. For DC power install a 1N4005 diode or
equivalent.
-
+
-
+
Siemens S10K30 MOV
(Metal Oxide Varistor)
or equivalent.
1N4005 diode
or equivalent.
1N4005 diode
or equivalent.
(control board)
(control board)
Maglock
Solenoid Lock
(not provided)
(not provided)
ACCESSORY WIRING
Acc Power +12 Vdc
Com (-)
(main control board)
Accessory Power Switched
Accessory Power Unswitched
Acc Power +12 Vdc
Com (-)
Com
Open
(main control board)
Three Button Control Station
Fire Department
Com
Fire Dept
Close
Stop
N.C.
MISCELLANEOUS WIRING
THREE BUTTON CONTROL STATION (4 Terminals)
• OPEN and COM: Opens a closed gate.
Hard open (maintained switch overrides external safeties and resets
alarm condition). If maintained, pauses Timer-to-Close at OPEN limit.
Opens a closing gate and holds open an open gate (within
line-of-sight).
• CLOSE and COM: Closes an open gate.
Hard close (maintained switch overrides external safeties and resets
alarm condition within line-of-sight)
• STOP and COM: Stops a moving gate.
Hard stop (maintained switch overrides Open and Close commands
and resets alarm condition). If maintained, pauses Timer-to-Close at
OPEN limit. Overrides Open and Close commands (within
line-of-sight).
FIRE DEPARTMENT OPEN INPUT (2 Terminals)
Acts as hard open.
Maintained input overrides (ignores) external safeties (photoelectric
sensor and edge), pauses Timer-to-Close momentary input logic as single
button control and safeties remain active, re-enables Timer-to-Close.
ACCESSORY POWER 12 VDC, MAX 500 mA (4 Terminals)
• SWITCHED: Switched ON with gate motion (stays on 5 seconds after
motion).
• UNSWITCHED: 12 Vdc voltage out to power accessories, always ON.