60
1. On or Off: show whether this thread is on or not
2. Recording Name: show this record’s name.
3. Sample Interval: from 20Hz to 1MIN (at present, it only supports 1Hz,
5s,10s,15s,30s and 60s).
4. Store Location: internal or external storage.
5. Start Time: represent that timing can start storage.
6. Enable Start Time Or Not: [Yes] or [No] button represents whether the previous
item Start Time will function. If Yes, it will start recording according to the set time, or it will
start at once.
7. Duration Time: the duration.
8. Storage: the reserved memory space for the current thread.
9. Recycle Store: when exceeding the set memory space, it will cover the early data
of the thread automatically.
10. Storage Format: Support HCN and RINEX.
11. FTP push: the current thread data will be set to sever push.
FTP push setting: three FTP severs can be set respectively in the FTP push setting menu.
Click the pop-up window, and users can set the server IP, port, remote directory, sever
description, use name, password and so on. FTP push can set the required sever to be
pushed. If users don’t need this function, click [Back] button.
FTP Push Recording: users can see a record list of FTP push in this menu.
Data Download: In this menu, the internal storage of i80 can be accessed by means of FTP.
All the static data stored by i80 threads can be found in repo folder and can be downloaded
by users. Both of the initial user name and password are ftp and can be modified in the Web
Service→FTP service.