EasyManua.ls Logo

Check Point QS-2 - Restoring from Gaia Clish

Check Point QS-2
49 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Restoring Factory Defaults
6000 and 7000 Appliances Getting Started Guide|48
7.
Reboot or turn on the appliance.
The appliance initializes and status messages are shown in the terminal emulation
program.
8. When the message "Press any key to see the boot menu" is shown, you have
approximately four seconds to hit any key to activate the Boot menu.
9. From the Boot menu, select the relevant Reset to factory defaults image.
10. Press Enter.
The appliance initializes and status messages are shown in the terminal emulation
program.
Restoring from Gaia Clish
To restore the appliance from Gaia Clish:
1.
Connect to the command line on the appliance.
2. Log in to Gaia Clish.
3.
Run:
set fcd revert <image_name>
Example:
MyAppliance> set fcd revert Gaia_R80.30
Warning! This command will erase all the current configuration on this appliance and will revert it
to the selected image.
Are you sure you want to continue such action? (Yes/No) [No]yes
Reverting to factory defaults Gaia_R80.30
MyAppliance>
Broadcast message from admin (Tue May 14 12:19:16 2019):
The system is going down for reboot NOW!
INIT: Sending processes the TERM signal