CHIYU TECHNOLOGY CO., LTD.
No.28, Renai Rd., Chiayi, 600, Taiwan Tel(886) 5-2835460 Fax(886) 5-2835458
BF-480M User’s Guide
- 17 -
Listen Port Number
Setting Factory Default Necessity
0 to 65535 50000 Required
If your device is acted as passive to accept commands from remote and the data be guaranteed to be received
by peer is your concern, then you can set BF-2300 as TCP Server. Be sure the value of item Listen Port
Number is same as your remote control application using.
Close Connection When Remote Idle
Setting Factory Default Necessity
0 to 65535 seconds 30 Required
If you want to keep the connection between BF-2300 and your remote control application always on, then set the
value of item Close Connection When Remote Idle to 0, otherwise, when the idle time of no any traffic on line
reach the setting value, BF-2300 will terminate this connection.
Access Password
Setting Factory Default Necessity
max password length is 31 characters None Optional
For security concern, you can input Access Password to protect your device, BF-2300 will authenticate whether
this TCP connection is valid by this password.
Keep Alive Check
Setting Factory Default Necessity
Disable/Enable Disable Required
Disable: Disable the check of TCP connection is still alive or not.
Enable: BF-2300 automatically send a Ping request to peer per each 30 seconds, the TCP connection will be
terminated if no response of Ping reply from peer.
Max TCP Connection
Setting Factory Default Necessity
1,2,3,4 1 Required
The allowed TCP connections accept by BF-2300 simultaneously. It is usually used when user needs to receive
data from different hosts simultaneously. When multiple hosts establish TCP connection to BF-2300 at the same
time, it will duplicate serial data and transmit to all hosts. When data comes from Ethernet port, it is sent on
first-in-first-out basis to serial port.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chiyu Technology BF-2300 and is the answer not in the manual?

Chiyu Technology BF-2300 Specifications

General IconGeneral
BrandChiyu Technology
ModelBF-2300
CategoryController
LanguageEnglish